- In bath rooms, all non-electrical metal work including must be bonded together and earthed.
(a) Bath tubs
(b) Water pipes
(c) Sinks
(d) All of above - Do not exceed per circuit
(a) 800 watts
(b) 10 lights or fans
(c) 15 lights
(d) All of above - Do not exceed per circuit - numbers of plug points for power circuit.
(a) 2
(b) 3
(c) 4
(d) 1 - Use heavily insulated, flexible cables for _______ appliances.
(a) Domestic & Commercial
(b) Industrial
(c) Commercial
(d) Domestic
Showing posts with label Installation Planning and Estimating. Show all posts
Showing posts with label Installation Planning and Estimating. Show all posts
Wednesday, 7 December 2016
Estimation of Electrical Wiring Multi Choice Questions & Answers
Estimation of Electrical Wiring Multi Choice Questions & Answers
Points : estimation of electrical wiring multi choice questions and answers, estimation of electrical wiring mcqs, objective
Multi Choice Questions & Answers
Estimation of Electrical Wiring True & False
Estimation of Electrical Wiring True and False
Points : estimation of electrical wiring true and false estimation of electrical wiring objective
True & False
- Anyhow material handling charges should not be more than 5% (max.) of material cost. (T)
- Overhead charges will generally be assumed as 10% to 25% of the total cost. (F)
- In large installations, tool charges aren’t be included. (F)
Estimation of Electrical Wiring blanks
Estimation of Electrical Wiring blanks:
Points : estimation of electrical wiring fill in the blanks, estimation of electrical wiring objective
Fill in the blanks
- Length of conduit required can be calculated by going through the plan of the building.
- Allow 10% of total length for wastage in any system.
- To calculate the length of wire, take the length of conduit after allowing wastage.
Saturday, 26 November 2016
Estimation of Electrical Wiring Short Question and Answer
Estimation of Electrical Wiring Short Question and Answer
Points : estimation of electrical wiring short question and answer
Q # 1: What should be the resistance of earth continuity conductor in the completed installation?
Answer: Circuit-breaker measured from the connection with the earth electrode to any points in the earth continuity conductor in the completed installation shall not exceed one ohm.
Q # 2: What should be the estimate of length of wire for wiring?
Answer: The length of wire can be taken as 2.5 times the length of conduit for looping system and 2 times for junction box system.
Q # 3: What should be the estimate of length of wire for switch boxes?
Answer: The length of the looping wire etc. in switch boxes shall not be lesser than 0.5 times of the height of the box itself.
Category
Installation Planning and Estimating
Tuesday, 15 November 2016
Power Wiring Installations
Power Wiring Installations
Points : power wiring installations, electrical power wiring installations
- I.E.E. rules Nos. 22, 50, 51 are to be satisfied,
- Wiring is to be installed either in surface conduits system or recessed conduit system.
- Earth wire of 8 S.W.G. must run along the pipes.
Category
Installation Planning and Estimating
Points To Be Considered While Preparing The Estimate
Points To Be Considered While Preparing The Estimate of Electrical Wiring
Points : points to be considered while preparing the estimate, building wiring estimating & costing, estimate the installation of an electrical distribution, electrical design and estimation
Points To Be Considered While Preparing the Estimate
- Length of conduit required can be calculated by going through the plan of the building.
- Allow 10% of total length for wastage in any system.
- To calculate the length of wire, take the length of conduit after allowing wastage.
- The length of wire can be taken as 2.5 times the length of conduit for looping system and 2 times for junction box system.
Category
Installation Planning and Estimating
Saturday, 12 November 2016
Fans and Exhaust Fans
Fans and Exhaust Fans
Points : fans and exhaust fans, exhaust fans, testing of installation, insulation resistance test, testing of earth continuity path, earthed electrode resistance test
Fans and Exhaust Fans
Fans The fans shall be suspended from hooks or shackles by means of suspension rods. Rubber insulators (shackle) shall be provided between the hooks and suspension rods. There shall be no joints in the suspension rod. The canopies on top of the suspension rod shall hide the suspension. The lead-in-wire from the ceiling rose shall be of 1.5 mm2 size and shall be protected from abrasion. The fan blades shall be kept at least 2.75 metres above the floor unless specified otherwise.
Category
Installation Planning and Estimating
Miniature Circuit Breakers
Miniature Circuit Breakers
Points : miniature circuit breakers, distribution boards
Miniature Circuit Breakers
The current limiting miniature circuit breakers shall be I.S.I. marked of category M 91M 3 conforming to International standards of IEC: 8828-1978, BS-3871 part 1 and VDE-0641.
(i) Standard: “Standard KOPP” brand from 0.5 A to 63A
M 9 SP, SPN, DP, TP, TPN (four poles).
(ii) M.D.S.: “Load Konkatk” brand S 210-series, from
(i) Standard: “Standard KOPP” brand from 0.5 A to 63A
M 9 SP, SPN, DP, TP, TPN (four poles).
(ii) M.D.S.: “Load Konkatk” brand S 210-series, from