Points : Characteristic of Shunt DC Generator
Building up of Voltage of a Shunt Generator at No Load
The curve plotted between the generated emf and shunt field current will be similar
to that. The generator excites itself due to residual magnetism and develops the
voltage as described below:
Line OP rep-resents the shunt field resistance. When the generator is started a
small emf (represented by OA is induced due to residual magnetism. This induced emf
causes a flow of current oa’ in the field circuit. This is obtained by drawing a
horizontal line from point A meeting the field resistance line at point ‘a’ and then
from point ‘a’ drawing perpendicular line meeting current axis at a’. When field
current is Oa, the generated emf. is a’a” which produces a field current Ob’, which
in turn produces a high voltage b’b”. This it is observed that effect is cumulative
and value of induced emf and field current increases until these reach point D, the
point of intersection of the shunt field résistance line and magnetic characteristic
obtained. Instantaneous increases in induced emf and field current are shown but in
practice flux increases gradually. OB is the maximum value of emf that can be
generated and generator cannot generate more than this voltage.
No comments: